Instruction manual
2. Preparation for Installation
33
2.2 Installation conditions
This section describes the requirements for installing the Switch. The installation
environment must meet these conditions.
2.2.1 General installation conditions
The General Installation Conditions for the Switch are listed below.
Table 2-1 General installation requirements for AX2200S series switches
Item
Model
AX2230S-24T
AX2230S-24P
Dimensions (W x D x H)
#1
445 x 230 x 43 mm 445 x 350 x 43 mm
Weight
#2
3.0kg 5.0kg
Input voltage Rating
Single phase 100 to 120 V AC, 200 to 240 V AC±
10% #3
Frequency
50/60 ± 3 Hz
Input current 0.5 @ AC100 V 6.7A @ 100 V AC
0.3A @ 200 V AC 3.4A @ 200 V AC
Power consumption 30.0W 470.0W
Heat emission 108kJ/h 1,692kJ/h
#1: Excluding the dimensions of connectors.
#2: Weight of the main device only. The weight of cables, rack mounting brackets, memory
cards and transceivers are excluded.
#3: The power supply cable included with the Switch supports only 100 V AC.
Table 2-2 General installation requirements for AX1250S series switches
Item
Model
AX1250S-24T2C
Dimensions (W x D x H)
#1
445 x 200 x 43 mm
Weight
#2
2.8kg
Input voltage Rating Single phase 100 to 120 V AC, 200 to 240 V
AC±
10% #3
Frequency
50/60 ± 3 Hz
Input current 0.18A @ 100 V AC
0.10A @ 200 V AC