Specifications

show cfm l2traceroute-db
624
Chassis ID Type: MAC Info: 0012.e254.dbf0
Ingress Port Type: LOCAL Info: Port 0/17
MP Address: 0012.e254.dc01 Action: OK
Egress Port Type: LOCAL Info: Port 0/25
MP Address: 0012.e254.dc09 Action: OK
>
Display items in Example 2
Table 35-17 Items displayed for the detailed linktrace database information
Item Meaning Displayed information
L2traceroute to
MP:<Remote MP>
The MAC address of the
destination remote MEP or
MI P.
The MAC address of the destination remote MEP or
MI P.
<Remote MAC address>: When the MAC address of a
remote MEP or MIP is specified.
<Remote MEP ID>(<Remote MAC address>): When a
remote MEP ID is specified.
Level Domain level 0 to 7
MA MA ID number Configured MA ID number
MEP MEP ID MEP ID for the Switch
VLAN VLAN ID Source VLAN ID
Time Send time
yyyy/mm/dd hh:mm:ss year/month/day
hour:minute:second
<TTL>
Time to Live 0 to 255
<Remote MAC
address>
MAC address of the
replying MP
The MAC address of the MEP or MIP that replied during
route verification
Forwarded Linktrace message
forwarded
Indicates that the replying MP forwarded the linktrace
message.
NotForwarded Linktrace message not
forwarded
Indicates that the replying MP did not forward the
linktrace message.
Hit Reply from the destination
remote MEP or MIP
Indicates that the reply was from the destination remote
MEP or MIP.
Last Egress ID of the source device that
forwarded a linktrace
message
The MAC address that identifies the device that
forwarded a linktrace message.
-- is displayed if this information is not in the received
linktrace reply.
Next Egress ID of the device that
received a linktrace
message
The MAC address that identifies the device that
received a linktrace message.
-- is displayed if this information is not in the received
linktrace reply.
The device MAC address is used for sending this
information from the Switch to another device.