Specifications
show cfm fault
617
Display items in Example 1
Table 35-12 Items displayed for failure information
Item Meaning Displayed information
MD Domain level 0 to 7
MA MA ID number Configured MA ID number
MEP MEP ID MEP ID for the Switch
Fault A failure is being detected. --
Cleared A failure has been cleared. --
Time Time a failure was detected The time a failure was detected by the MEP
If multiple failures have been detected, the time each failure
was detected is displayed.
yyyy/mm/dd hh:mm:ss year/month/day
hour:minute:second
- is displayed if the failure has been cleared.
Example 2
The following figure is an example of displaying detailed information about a CFM failure.
Figure 35-9 Example of displaying detailed failure information
> show cfm fault domain-level 7 detail
Date 2009/10/29 07:28:32 UTC
MD:7 MA:1000 MEP:1000 Fault
OtherCCM : - RMEP:1001 MAC:0012.e254.dbff VLAN:1000 Time:2009/10/29 07:18:44
ErrorCCM : On RMEP:1001 MAC:0012.e254.dbff VLAN:1000 Time:2009/10/29 07:27:45
Timeout : On RMEP:1001 MAC:0012.e254.dbff VLAN:1000 Time:2009/10/29 07:27:20
PortState: -
RDI : - RMEP:1001 MAC:0012.e254.dbff VLAN:1000 Time:2009/10/29 07:23:45
MD:7 MA:1010 MEP:1011 Cleared
OtherCCM : -
ErrorCCM : - RMEP:1010 MAC:0012.e254.dc01 VLAN:1011 Time:2009/10/29 07:19:01
Timeout : - RMEP:1010 MAC:0012.e254.dc01 VLAN:1011 Time:2009/10/29 07:18:44
PortState: -
RDI : - RMEP:1010 MAC:0012.e254.dc01 VLAN:1011 Time:2009/10/29 07:21:01
>
Display items in Example 2
Table 35-13 Items displayed for detailed failure information
Item Meaning Displayed information
MD Domain level 0 to 7
MA MA ID number Configured MA ID number
MEP MEP ID MEP ID for the Switch