Specifications

line console speed
27
line console speed
Specifies the communication speed of CONSOLE (RS-232C). If a user has already logged
in from CONSOLE (RS-232C) when the communication speed is changed, the speed
changes immediately. If the communication speed is changed from a remote operation
terminal while login authentication for a user who is trying to log in from CONSOLE
(RS-232C) is in progress, the authentication might fail.
Syntax
line console speed <Transmission rate> [save]
Input mode
User mode and administrator mode
Parameters
<Transmission rate>
Specifies the communication speed of CONSOLE (RS-232C).
Specifiable communication speeds:
1200, 2400, 4800, 9600, 19200
Operation when this parameter is omitted:
This parameter cannot be omitted.
save
Saves the new communication speed setting to the internal flash memory.
Operation when this parameter is omitted:
The new communication speed setting is not saved to the internal flash
memory. If you restart the device, the old communication speed setting is
used.
Operation when this command is not used:
CONSOLE (RS-232C) operates at 9600 bps.
Example
Change and save the communication speed.
> line console speed 19200 save Press the Enter key.
Do you wish to continue? (y/n): y
Display items
None
Impact on communication
None
Response messages
None
Notes
Using this command to change the communication speed immediately changes the
speed. If the communication speed is changed from a remote operation terminal