Specifications
show port
160
Item Meaning Displayed information
Status Port state up: Active (normal operating state).
down: Active (a line failure has occurred).
inact: The port is inactive
#1
The following can cause a port to become inactive:
- The inactivate command, which stops
operation
- The standby link functionality of link aggregation
- The BPDU guard functionality of a Spanning Tree
Protocol
- The storm control functionality
- Detection of a unidirectional link failure by the
UDLD functionality
- The L2 loop detection functionality
dis: Operation has been stopped by using the
shutdown or schedule-power-control
shutdown interface configuration command.
Speed Line speed 10BASE-T: 10BASE-T
100BASE-TX: 100BASE-TX
1000BASE-T: 1000BASE-T
100BASE-FX: 100BASE-FX [AX1250S]
1000BASE-LX: 1000BASE-LX
1000BASE-SX: 1000BASE-SX
1000BASE-SX2: 1000BASE-SX2
1000BASE-LH: 1000BASE-LH
1000BASE-BX10-D: 1000BASE-BX10-D
1000BASE-BX10-U: 1000BASE-BX10-U
1000BASE-BX40-D: 1000BASE-BX40-D
1000BASE-BX40-U: 1000BASE-BX40-U
-: Speed is unknown (Appears when Status is not up.)
Duplex Full duplex/half duplex full: Full duplex
full(auto):Full duplex (resulting from
auto-negotiation)
#2
half: Half duplex
half(auto): Half duplex (resulting from
auto-negotiation)
-: Duplex is unknown (Appears when Status is not
up.)
FCtl Flow control on: Flow control is enabled.
off: Flow control is disabled.
-: Status is not up.
FrLen Maximum frame length Displays the maximum frame length of a port in octets.
-: Status is not up.
ChGr /Status Channel group and status The channel group to which the port belongs and the
status.
Link aggregation channel group number:
up: Data packets can be sent and received.
down: Data packets cannot be sent or received.
dis: Link aggregation is disabled.
For a port that does not belong to link aggregation, -/-
is displayed.