Specifications

show interfaces
148
Item Displayed information
Detailed information Meaning
<port status>
active up
Running
active down
Stopped
inactive
#1
The port is in the inactive status.
The following can cause a port to become
inactive:
Operation stopped by the
inactivate command.
Due to standby link function of link
aggregation
Due to the BPDU guard functionality of
the Spanning Tree Protocol
The storm control functionality
Detection of a unidirectional link failure
by the UDLD functionality
The L2 loop detection functionality
disable
Operation was stopped by using the
shutdown or
schedule-power-control shutdown
interface configuration command.
<line type>
1000BASE-T full(auto)
100BASE-T full duplex
(Line type determined by auto-negotiation.)
100BASE-FX full [AX1250S] 100BASE-FX full duplex
100BASE-FX full(auto) [AX1250S]
#2
100BASE-FX full duplex
1000BASE-LX full
1000BASE-LX full duplex
1000BASE-SX full
1000BASE-SX full duplex
1000BASE-SX2 full
1000BASE-SX2 full duplex
1000BASE-LH full
1000BASE-LH full duplex
1000BASE-LX full(auto)
1000BASE-LX full duplex
(Line type determined by auto-negotiation.)
1000BASE-SX full(auto)
1000BASE-SX full duplex
(Line type determined by auto-negotiation.)
1000BASE-SX2 full(auto)
1000BASE-SX2 full duplex
(Line type determined by auto-negotiation.)