Specifications

show environment
82
Item Displayed information Displayed information
Mode Fan operation mode -: No fan
1 (silent): Reducing switch noise takes
priority.
2 (cool): Keeping the switch cool takes
priority.
Temperature environment Temperature environment
display
--
Main
#1
Intake temperature
information
Converted value of the internal temperature
Note, however, it shows - for 60 minutes after
the Switch starts.
Warning level
#2
Operating condition level normal: Normal
caution: Outside the normal range
Temperature-warning-level
current status
#3
Information of the
temperature for outputting
operation messages
mm/nn degree C
mm: Current intake temperature (converted
value of the internal temperature)
nn: Temperature that is set with the system
temperature-warning-level
configuration command
Temperature-warning-level
average status
#4
Information of the average
temperature for outputting
operation messages
mm/nn degrees C period xx day(s)
mm: Current intake average temperature
(converted value of the internal average
temperature)
nn: Temperature that is set with the system
temperature-warning-level average
configuration command
xx: Time period of calculating the average
temperature
#5
Accumulated running time Cumulative operating time
#6
total: Total device run time since startup
critical: Run time in the caution state
#1
The intake temperature is a converted value of the internal temperature. Therefore,
the intake temperature might be quite different from the actual ambient temperature
depending on the installation environment of the device, the number of the used
ports, or the SFP type. When using the cooling fan monitoring and controlling
functionality on the AX1240S-48T2C, the intake temperature might also be quite
different from the actual ambient temperature depending on the ON or OFF status of
the FAN.
#2
Warning level is displayed as a result of evaluating the changes in internal
temperature.