Specifications

show environment
81
show environment
Displays the fan status, the power unit status, the status of the temperature in the chassis,
and the cumulative operating time.
Syntax
show environment [temperature-logging]
Input mode
User mode and administrator mode
Parameters
temperature-logging
Displays the temperature history of the target switch.
Operation when this parameter is omitted:
The environmental status of the switch is displayed.
Example 1
The following shows an example of displaying the operating status.
Figure 7-3 Example showing the result of executing the show environment command
> show environment
Date 2012/07/06 10:10:45 UTC
Fan environment
Fan : active
Mode : 1 (silent)
Temperature environment
Main : 30 degrees C
Warning level : normal
Temperature-warning-level current status : 30/40 degrees C
Temperature-warning-level average status : 27/35 degrees C period 30 day(s)
Accumulated running time
total : 808 days and 0 hours
critical : 0 days and 0 hours
>
Display items in Example 1
Table 7-3 Information displayed by the show environment command
Item Displayed information Displayed information
Fan environment Fan environment display --
Fan Fan operating status -: No fan
active: Running
fault: A fault has occurred.
inactive: Stopping due to the cooling fan
monitoring and controlling functionality (only
for the AX1240S-48T2C model)