User Guide

Technical data
Supply voltage (nom. 12V) 7.0...16.0V
DC
Current consumption (12VDC/quiescent) typ. 3.5mA
-- alarm condition 5mA
Alarm output relay, opens at alarm
-- contact 30V
DC /100mA
Electronic alarm output (short-circuit proof £16V) alarm 0V
-- alarm hold time 2.5s
Tamper surveillance microswitch,
closed with cover in place
-- contact rating 30V
DC /100mA
-- supply voltage 6V...<7V alarm
Test point terminal 9 analog integrator signal
-- quiescent level <0.1V
-- integration start 2.5V
-- max. interference level 3.4V
-- alarm threshold (without load) 4.0V
Operating radius 1.5m
Coverage area 7m
2
Coverage volume 0.5m
3
Sensitivity, adjustable in 4 levels
Response time, adjustable in 2 levels
Shock settings 4 levels
Ambient conditions:
-- operating temperature --20 ...+60 C
-- storage temperature --50 ...+70 C
-- humidity, DIN class F <95%
-- housing protection category IEC IP43
-- insensitive to RD interferences
(0.1MHz...1GHz) (IEC801-3) £15V/m
-- immunity to spike voltages on supply line
-- differential (IEC801-5) 1kV
-- common mode(IEC801-5) 3kV
Elements supplied with detector
1 Seismic detector
1 Mounting instructions
1 Mounting template
3Cablestraps
GM526 Seismic detector 503 536
GMXP Mounting plate 276 737
GMXC2 Conduit connection sleeve 16mm 502 184