Installation guide

© 2003 Directed Electronics, Inc. Vista, CA 3
what is included
The control module Two 4-button remote transmitters
The plug-in LED system status indicator The plug-in Valet
®
/Program switch
An on-board zone 2 impact sensor A high-powered siren
The 12-pin primary harness The 7-pin door lock harness
The 3-pin auxiliary harness The plug-in starter interrupt harness
primary harness (H1) wire connection guide
______
______
______
______
______
______
______
______
______
______
______
______
This wire supplies (-) ground as long as the system is armed. This output ceases as soon as the system is disarmed. This
wire can be used to turn on an optional sensor or to control an optional accessory, such as a window module or
pager.
H1/1 ORANGE (-) ground-when-armed 500 mA output
RED/WHITE (-) 200 mA CHANNEL 2 VALIDITY OUTPUT
RED (+)12V CONSTANT POWER INPUT
BROWN (+) SIREN OUTPUT
YELLOW (+) IGNITION INPUT, ZONE 5
BLACK (-) CHASSIS GROUND INPUT
VIOLET (+) DOOR TRIGGER INPUT, ZONE 3
BLUE (-) MULTIPLEX TRIGGER INPUT, ZONE 1
GREEN (-) DOOR TRIGGER INPUT, ZONE 3
BLACK/WHITE OUTPUT OF INTERIOR LIGHT ILLUMINATION RELAY #30
WHITE/BLUE (-) 200 mA CHANNEL 3 VALIDITY OUTPUT
WHITE (+/-) SELECTABLE LIGHT FLASH OUTPUT
ORANGE (-) 500 mA GROUND-WHEN-ARMED OUTPUT
H1/1
H1/2
H1/3
H1/4
H1/5
H1/6
H1/7
H1/8
H1/9
H1/10
H1/11
H1/12