Specifications
17
Series RMB Hot Runner Controller Instruction Manual
7. Frequently Asked Questions
7.1 Introduction
Before you call for technical support, please look at this section to see if your
question is covered here. If you do call for technical assistance, be ready to
supply the following information:
• complete model number of controller (and firmware version if known)
• symptoms of the problem
• unusual events, if any, that preceded the problem
• remedies you have already tried
7.2 FAQs
7.2.1 How do I change from a J to a K thermocouple?
Every Series RMB controller is shipped ready to accept input from a J thermo
couple. If you plan to use a K thermocouple for input, you must set
SW2-switch 2 to ON as described in Section 3. Read the safety warnings at
the front of this manual before changing switch settings.
7.2.2 Do I have to calibrate a new controller?
No
7.2.3 Why doesn’t the displayed PV match the value on a
thermometer in the process?
Unless the thermometer and the sensor providing input to the controller are very
close to one another, their readings will not match in some applications, because
of temperature variations within the process.
7.2.4 I turned on the power; why doesn’t the controller light up?
If SafeChange is enabled, but the mainframe does not support SafeChange, the
controller will not work. Instructions for checking to see if a mainframe supports
SafeChange are in 3.2.