Trilogy Series DL2800 Programming Instructions ALARM LOCK PLUG IN THEN ENTER YOUR CODE ALARM LOCK DL2800 Trilogy Series Standalone Access Control System ALARM LOCK OI246A 1/02 1
Features ----------------------------------------------------------------------------------------------------- 4 Audit Trail ------------------------------------------------------------------------------------------------- 4 User Features ------------------------------------------------------------------------------------------- 4 150 Scheduled Events -------------------------------------------------------------------------------- 4 Keypad and Download Programming -------------------------------------------
Programming Functions ---------------------------------------------------------------------------- 11 New Master Code --------------------------------------------------------------------------------------- 11 Add/Delete/Change User Codes -------------------------------------------------------------------- 11 Disable User ---------------------------------------------------------------------------------------------- 11 Enable User--------------------------------------------------------------------------------
------- AUDIT LOG ------04/07/98 13:06:35 Tue 13:01:59 001 PROGRAM 56 13:01:29 001 PROGRAM 57 13:00:53 001 ENTRY 13:00:26 013 ENTRY 13:00:03 012 ENTRY 12:56:27 001 PROGRAM 2 12:56:27 001 PROGRAM 40 12:56:04 001 PROGRAM 39 12:55:00 NEW CLCK TIME 12:01:39 OLD CLCK TIME 12:00:45 RAM TEST:PASS 12:00:45 POWER UP ------------------------- Audit Trail - 1000 Events • Time/Date Stamped Log of all Entries • Logs program mode changes • View Audit Trail: Print using the AL-IR1 hand-held printer Upload using Alarm Loc
Programmable Timeout Functions Timeout functions allow enabling/disabling users and enabling passage mode for a time period without requiring the user to return to the lock. Users Associated for more than one group Note: If a user is associated with more than one group, all associated groups would have to be disabled before the user is disabled. Service Code User number 300 is the service code. Once the service code is used, it is disabled. Function 9 is used to re-enable the service code.
Battery Replacement When a valid code is entered and the batteries are weak the lock LED will light amber, and the sounder will sound for 4 seconds. The DL2800 uses 5 AA-size 1.5 volt alkaline batteries. The lock will function with weak batteries; however be sure to replace the batteries as soon as possible. Remove the screw at the bottom of the housing and remove the cover. Remove battery box and replace all 5 batteries quickly - within 2 minutes.
Lock Operation Programming - Notes Important: Before attempting to program any codes or functions, Note the following: • While the lever or knob may be rotated at any time, the latch will not be engaged to unlock the door unless a valid code has been entered. • When a valid code is entered, the lock will unlock immediately and remain unlocked for about 5 seconds (or longer, if reprogrammed by functions 52 and 53). LED Indications Key Press - The red LED will light momentarily whenever a key is pressed.
Battery Installation Remove the back cover and battery box assembly. Install batteries as per the key on battery box top cover. Close and re-install the battery box. The lock will beep 3 times. To load the default program press any key within 5 seconds, the lock will beep slowly while the default values are loaded and beep rapidly upon completion. Entering Program Mode 1.
User Programming User code conflicts Add a Basic User Code Care should be taken not to Program a User Code of 987. Use Function 2, and add the new user as program a new user code which User 12 (Users 12-50 are Basic Users). Refer to Function 2 (page 11). matches the first digits of any other ;2 ;12 ;987: User Number (12) User 12’s Code Add another Basic User Code Program a User Code of 246. Use Function 2, and add the new user as User 13. Refer to Function 2 (page 11).
Tri-Color Status LED Keypad Programming Infrared LED (Printer) Entering Program Mode PC Interface/AL-DTM 1. Enter Master Code 1 2 3 4 5 6 Default Master Code 2. Enter “BeepBeep” “BeepBeep” ; “BeepBeep” “BeepBeep” Sounder will sound 2 short beeps 4 times to indicate the program mode is active. Program Mode The keypad sounder will beep every 6 seconds and the keypad LED will flash green every 6 seconds while in program mode when no keys are pressed.
USERS 1. New Master Code (User Number 1) ;[______] ;1 • Master Code must be 6 digits-only. NOTE: Following a power up, Function 1 (New Master Code), must be accessed before any other programming function is permitted. 2. Add/Delete/Change User Codes 2-200 • • • • ;[______]: M ;[___] ;2 User Number must be between 2 and 200.
USERS ;5 5. User Enable with Timeout (Enter Timeout, XXX Hours) ;[___] ;[___]: (User Number) • User Numbers must be between 2-200 (plus 299 and 300). • Hours must be between 1 - 999 (XXX Hours) 2 User Lockout Mode Enables/Disables all User Codes (Except User 1 Code) from operating the lock. Note: No other programming functions or schedules will re-enable users. Users must be reenabled with function 7. 6. Enable Total User Lockout ;6: 7. Disable Total User Lockout ;7: 8.
CLEAR FUNCTIONS 12. Clear All Schedules and Timeout Functions ;12 ;000: Clears all programmed Schedules and all Timeout Functions. Includes Schedule Functions 72 to 93. Includes Timeout Functions 5, 25 to 34 and Function 47. NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound if more than 4 Timeout Functions are attempted to be programmed. 13. Clear All Timeout Functions ;13 3 ;000: Clears all programmed Timeout Functions.
NOTE: GROUPS Clear All Timeout Functions by entering Function 13. Group Disable/Enable with Timeout (Enter Timeout, XXX Hours) • Hours must be between 1 - 999 • Enter the functions below to Enable/Disable groups for the amount of time entered in hours. NOTE: Only 4 Timeout Functions are allowed at any one time. An error beep will sound if more than 4 Timeout Functions are attempted to be programmed. 25. Timed Disable Group 1 ;25 2 ; [___]: (XXX Hours) 26.
CLOCK SETTINGS 38. Set Date ;38 ;[ ______]: (Date) • Use month day year format - MMDDYY - single digit months and days are entered with a preceding zero. • Enter Only the last two digits of the year. 3 For Example: March. 8, 1998; Enter: ;38 ;03 08 98: 39. Set Time ;39 ; [____]: (Time) • Time must be 4 digits. • Use 24 Hour Format (add 12 hours to program P.M. times) 3 For Example: To set time to 8:25 P.M.; Enter: ; 3 9 ;2025: For Example: To set time to 8:25 A.M.
CLOCK ADJUST Clock Adjust • Number of seconds to Speed Up/Slow Down clock each day must be 0-55 seconds. Always consider the current setting when using this function. (Use of this function is not cumulative.) For example, if the clock needs to be sped up 10 seconds per day and the current setting is 10, program 20 seconds using Function 43. 4 Example 1: Clock is losing 13 seconds every day, enter: ;43 ; 1 3 :. This example assumes that the clock adjust setting was at the factory default of zero.
PASSAGE MODE Passage Mode Enable/Disable - Schedule will not Override • Allows passage through the door without the need for a code using Function 48. ReLock using Function 49. • Programmed Schedules will not override the state of the lock using functions 48 and 49. If it is required that programmed schedules do override passage mode, Enable/Disable Passage mode using Functions 45/46. Use Function 50 to return the lock to scheduled functions. 48. Enable Passage Mode ;48: 49.
PRINTER Hold the printer’s tab perpendicular to the Lock’s infrared LED as shown in Figure 1 and Figure 2. If the printer has been idle for some time, press the paper feed button to wake up printer. Printer Tab Infrared LED Infrared LED Printer Tab 123 456 789 :0; DL2800 to Printer - Side View DL2800 to Printer - Front View Figure 1 55. Print Audit Trail Figure 2 ;55: Hold the printer over the lock's infrared sensor as shown in Figure 1 and Figure 2.
AL-DTM 59. AL-DTM Door Number ;59 ; [__]: Door Number) • Door Number must be between 1- 96. 4 For use with Alarm Lock’s AL-DTM Data Transfer Module. Using the AL-DTM up to 48 locks (96 for AL-DTM2) can be Downloaded/Uploaded and History LOGs can be retrieved. Enter a door number for each lock. After configuring the AL-DTM, using Alarm Lock's DL-WINDOWS Software, any of the following data transfers can be initiated by plugging the AL-DTM into the lock and simply entering User Code 299 at the lock.
67. Reserved 68. Reserved ENTER KEY Enter Key Enable/Disable (Allows Programming of Codes that Match the 1st digits of other Codes) • When this function is enabled the user must press the : key after a user code entry, this allows user codes which are subsets of other user codes. 4 Example: 1 2 3 : is a valid user code; 1 2 3 4 : is a valid user code 69. Enable : as Enter Key ;69: 70. Disable : as Enter Key ;70: 71.
SCHEDULES NOTE: Clear All Schedule and Timeout Functions by entering Function 12. Scheduled Group Enable/Disable Use the functions below to Enable/Disable Groups at the time programmed. • For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday and 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, 0 for all days of week. 74. Schedule Enable Group 1 ;74 3 ;[_] (Day) 75. Schedule Enable Group 2 ;75 ;[_] (Day) 76.
QUICK SCHEDULES Quick Schedules - Enable Group • Group number must be 1-4 Enter the number of the group that is to be enabled for the time specified for the Quick Schedules below: 84. Business Quick Schedule 7AM-5PM, Monday - Friday 85. Day Quick Schedule 7AM-5PM, All days 86. Evening Quick Schedule 3PM-1AM, All days 87.
90. Reserved 91. Reserved Scheduled Group 4 Enable (Group 1 Activated) • For day enter: 1 for Sunday, 2 for Monday, 3 for Tuesday, 4 for Wednesday, 5 for Thursday, 6 for Friday and 7 for Saturday, 8 for Monday to Friday, 9 for Saturday and Sunday, 0 for all days of week. • Enter time of day in 24 hour format. Enter the Open and Close Window Functions below to set up a Window where if any Group 1 User Code is entered within the programmed window Group 4 will be enabled.
Note: Advanced User Programming Add a User that is a member of Group 2 & Group 3 Program a User Code of 789 that is a member of Group 2. Refer to Function 2 (page 11). Use Function 2, and add the new user as User 101 (Users 101-150 are members of Group 2): Add User 101: ;2 ;101 ;789: Make User 101 also member of Group 3 using Function 35: ;35 ;101 ;23: Note: Although User 101 is by default a member of Group 2, Group 2 must be included when using Function 35 or the Group 2 association will be removed.
Default Values are shown in parentheses.
User Number (1-200, 299 and 300) User Code (3-6 digits) Group Association 1 2 3 Program Set Ability 4 Note: For a complete list of user codes obtain a print out from either the remote printer (Program Function 56) or using the DL-WINDOWS Downloading Software.
Day(s) Function Number Up to 150 scheduled functions can be programmed.
ALARM LOCK LIMITED WARRANTY ALARM LOCK SYSTEMS, INC. (ALARM LOCK) warrants its products to be free from manufacturing defects in materials and workmanship for twelve months following the date of manufacture. ALARM LOCK will, within said period, at its option, repair or replace any product failing to operate correctly without charge to the original purchaser or user.