Installation Guide
6
MODE NAME FEATURE DETAILS JUMPER
POSITIONS
For Multiple Door Installa-
tions
A PG21 installed on several doors each with its unique siren sound.
Four siren sounds: Sweep, Pulsing Sweep, Steady, Pulsing Steady.
Set a different siren sound for each door in order to easily identify
which door has been accessed. Jumpers 1 and 2 are config-
ured.
Sweep
Pulsing Sweep
Steady
Pulsing Steady
Door Ajar Mode
Exit/Entry Door without Key
Needed
No Key Passage Mode
Friendly Mode
You can enter or exit without key. Door can remain open without
alarm for length of delay time. If door left open past delay time,
siren will sound until door is closed.
Closing door turns siren off and rearms (no key required--just close
door).
Auto re-arming does not sound a chirp.
Add a delay so you can enter or exit without an alarm:
Add Arming/Exit Delay of 15 seconds: J5 down only
Add Alarm/Entry Delay of 15 secs: J6 down
Add Alarm/Entry Delay of 1 minute J6 up, J7 down
Add Alarm/Entry Delay of 2 mins J6 & J7 down
Example shown:
J4 down--Non-
Latching Alarm.
J6 down--15 second
"Passage Time/
Door Open Time"
"On/Off" Mode
Manual Arm/Disarm Door
Manual Arming Mode ("On /Off" mode. See page 2, Configuration).
Torsion Spring disconnected from Cam Assembly.
Manually arm or disarm system for extended periods of time. No "Auto-
rearm".
Mechanical configuration required.
All Jumpers up
Back Door Annunciator
For use only with "On/Off" mode when unit is disarmed with a key.
PG21 will beep for 2 seconds when door is opened while disarmed.
Jumper J9 determines volume of chirp: ("up" = low volume, "down"
= high volume).
J8 & J9 down
1 2
1 2
1 2
1 2
CONFIGURATION EXAMPLES (cont'd)
1 2
3
4
5 6 7
8
9
1 2
3
4
5 6 7
8
9
1 2
3
4
5 6 7
8
9