Installation Guide

5
MODE NAME FEATURE DETAILS JUMPER
POSITIONS
Factory Default
Highest Security
Fire/Emergency Exit Door
Nursing Home Stairwell Door
Delivery Door--Latching
Alarm
Opening door without key while armed causes a latching alarm (key
required to silence).
Key required to exit and to turn off siren after an alarm.
Alarm siren time-out: 2 minutes.
After time-out, LED flashes.
Door can be propped open indefinitely, as follows: Turn key to the left
while opening door (this avoids alarm). After door is opened, re-
lease key. Door can be left open indefinitely. When door closes,
door rearms (with a beep).
All Jumpers Up
Entry/Exit Door with Key
Needed
Key required to enter and exit--but door must be closed within selected
time or alarm occurs.
Key required to turn off siren after an alarm.
Opening door without key while armed causes a latching alarm after
set delay time.
Alarm siren time-out: 2 minutes.
After time-out, LED flashes.
Add a delay so you can enter or exit without an alarm:
Add Arming/Exit Delay of 15 seconds: J5 down only
Add Alarm/Entry Delay of 15 secs: J6 down
Add Alarm/Entry Delay of 1 minute J6 up, J7 down
Add Alarm/Entry Delay of 2 mins J6 & J7 down
Example shown:
J5 down--15 second
Arming/Exit Delay
J6 down--15 second
Alarm/Entry Delay
Delivery Mode
Delivery Door--Non-Latching
Alarm
Exit Door with Instant Alarm--
No Key needed to si-
lence
Instant non-latching alarm when door is opened, siren turns off and
alarm resets when door is closed.
For delivery, turn key to left, open door and prop door open; auto-
rearms when the door closes.
J4 down
2-Minute Delivery Door
with non-latching alarm
Door Ajar Mode with 2 min-
ute delay.
No key needed to open door without alarm, but if door is left open more
than 2 minutes, alarm sounds.
No key needed to silence, just close door.
Allows door to remain open up to 2 minutes without an alarm.
J4, J6 and J7 all down
1 2
3
4
5 6 7
8
9
1 2
3
4
5 6 7
8
9
1 2
3
4
5 6 7
8
9
Fig. 6. Jumper Positions. Jumpers 1-9 shown in
factory default positions--all jumpers "up".
1 2
3
4
5 6 7
8
9
Clear
1 2
3
4
5 6 7
8
9
CONFIGURATION EXAMPLES
Use the PG21 for a variety of applications--emergency fire escape doors, nursing home stairwell doors, rear restaurant doors, and many others.
To change the way the PG21 operates when in use, two areas of the PG21 can be configured: (a) the PC Board jumpers and (b) the Torsion
Spring connection. Listed below are pre-defined modes for typical applications. Simply select a mode, configure the jumpers and/or spring, and
put your PG21 into use. NOTE: "Always Armed" mode (Torsion Spring connected--factory default) is in effect unless otherwise stated.
Cam
Assembly
Torsion
Spring
Fig. 7. Torsion Spring connected--"Always Armed" mode (left) and discon-
nected--"On/Off" mode (right). See CONFIGURATION on page 2
continued