Specifications
Time 
Units
Abort Delay (See Note 1) 
-seconds
Exit Delay (See Note 1)
seconds
Entry Delay (See Note 1)
seconds
Relay Time-Out (See Note 2) 
minutes
Max. Programmable Time
75
 seconds
150 seconds
150 seconds
75 minutes
Notes:
1. 
If time location left blank, feature does not activate.
2. If time location left blank, feature remains active until system disarmed.
Trouble. An 
abnormal zone condition (a break in loop). Trouble on a Burglary Zone is
indicated by a sounder beep on arming (does 
not
 apply to selective- or group-bypassed zones).
If Auto-Bypass has been removed from a Burglary Zone, that zone will go into alarm on
arming.
A Day-Zone trouble is indicated by a flashing Ready LED and a pulsing sounder; the digital
readout displays the troubled zone(s). Keypad is reset by Key 
[9].
Voltage
 Open 
Loop
 NOL 
Lug).
 To convert one or more zones from normally closed to
normally open, install a 330-ohm VOL resistor (supplied) across each zone’s input terminals,
and connect a 
normally-open
 device between the zone’s positive 
(
 + 
)
 terminal and Terminal
17. See example, illustrating Zone 5, below.
(
)
-
Zone 
5-a
N/O Device 
330 ohms
24-Hour Protection, 
A zone that provides protection at all times, whether or not system is
armed. Neither Ready nor Armed LED will indicate the condition of a zone programmed for
24-Hour Protection.