69. Enable : as Enter Key
Enter Key Enable/Disable (Allows Programming of Codes that Match the 1st digits of other Codes)
; 7 0 :
70. Disable : as Enter Key
When enabled, the user must press : after a User Code entry, allowing User Codes
to be subsets of other User Codes. For example:
1 2 3 : is a valid User Code;
1 2 3 4 : is also a valid User Code
4
ENTER KEY
71. Reserved
Programming Functions (cont'd)
; 6 7 ; [ _ _ ] :
(Event Number)
67. Add Relay Features
RELAY FEATURES
Use Function 67 to program one or more lock events and the Relay will energize when the programmed event(s) listed below oc-
curs. For example, program ; 6 7 ; 3 : and when an attempted entry fails (such as a User who enters an
incorrect or un-programmed User Code), the Relay will energize for 2 seconds. Note: For more information about the Remote In-
put, see page 10 (Wiring, Remote Input) and page 22 (Function 65).
1. Remote Input switch closed and Function 65 Remote Input
enabled. Because the Remote Input is enabled by factory default,
the Relay will energize when the Remote Input switch is closed.
7. Scheduled Lock Event. Relay energizes for 2 seconds when lock
is locked by a Schedule.
2. Remote Input switch closed and Function 64 Remote Input
disabled. If the Remote Input is disabled with Function 64, the Re-
lay will energize when the Remote Input Switch is closed.
8. Scheduled Unlock Event. Relay energizes for 2 seconds when
lock is unlocked by a schedule
3. Failed attempted entry. Relay energizes for 2 seconds when an
attempted User Code entry via the keypad fails.
9. Lock Out. Relay energizes for 2 seconds when a Lock Out occurs
(i.e. number of attempts is exceeded, see Function 60).
4. Disabled User or Group. Relay energizes for 2 seconds when a
disabled User or disabled Group member enters a User Code.
10. Ambush. Relay energizes for 2 seconds when Ambush is tripped.
See Function 66, page 22 and "Ambush Function" below.
5. Follow Access Granted. When a valid User Code is entered into
the keypad and the lock unlocks, the Relay energizes for 2 seconds.
Compare with Event 31.
11. First Key Press. Relay energizes for 2 seconds at the first key
press of any sequence.
6. Group 1 User Code. Relay energizes for 2 seconds when a sched-
uled Group 1 User Code is entered. See Function 90, page 26.
4
68. Delete All Relay Features added by Function 67.
; 6 8 ; 0 0 0 :
Enter ; 6 8 ; 0 0 0 : to delete all Relay Features added by Function 67.
4
Ambush Function
1. Connect relay to a device able to properly monitor dry contacts for an Ambush condition.
2. Program the Relay for Ambush Tripped using Program Function 67(10) above.
3. Set the Ambush Code using Program Function 66.
4. When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds.
Notes: The Ambush Code defaults to 99. An error will sound if you try to program a new User Code starting with the Ambush Code.