1.2.14 Set Alarm Control
See “Alarm Control” on page 1 in section 12 for a complete description of how to enable, use, and
disable the Alarm Control feature in Doors.
The Alarm Control parameter allows an operator to enable the alarm control feature of the Doors
program for use with a NetworX NX-8E Alarm Panel.
NOTE: In order for the Alarm Control feature to be enabled, a PXL-510 controller must be set as the
master controller and connected to a NetworX NX-8E Alarm Panel. For further information on
installing necessary controllers for use with the alarm control feature, refer to the PXL-500/PXL-510
Quick Start Guide (P/N 01918-001) and the NetworX NX-8E Alarm Panel Application Note (P/N
01919-001).
The program default is for Alarm Control to be OFF.
1. From the System Options tab, click on the button. The System Options
window will reveal the Alarm Control field (see Figure 2-28).
Figure 2-28: Alarm Control Field
2. If your system is not using a PXL-510 master controller connected to a NetworX NX-8E Alarm
Panel, Doors will not allow the Alarm Control feature to be enabled.
3. To enable use of the Alarm Control feature in connection with a PXL-510 master controller, click
in the check box beside the Alarm Control ON field. When there is a check in the box, the feature is
enabled. To disable this field, click in the check box again and remove the check mark (this is the
default value).
NOTE: A few changes are made to the access control databases when the Alarm Control feature is
enabled. These changes add the fields necessary to manage the alarm system. For simplicity in
explaining the features in the Doors program, the majority of this Users Guide assumes that the Alarm
Control feature is not enabled. Alarm Control related features are explained in detail in “Alarm
Control” on page 1 in section 12.