Specifications
Doors
TM
Users Guide Keri Systems, Inc.
14-4 Section 14: Dual Verification 01914-014 Rev. 5.5
1.1 Excessive PIN Attempts
A user may have a maximum of 6 attempts to enter the proper Primary ID and Secondary ID before the
reader or keypad gets locked out (not allowing any attempts) for a pre-set period of time.
1. To enable this feature, click on the Excessive PIN Attempts ON box. When there is a check in the
box, the feature is enabled. To disable this field, click in the check box again and remove the check
mark (this is the default value).
Once Excessive PIN Attempts has been enabled, a lock out time must be set. This is the period of time
(in seconds) that the reader or keypad will lock out access following 6 failed attempts to enter a valid
Primary and Secondary ID.
2. To set the lock out time, click in the Lock Out Time field and enter the number of seconds, ranging
from 5-255 seconds, that the reader or keypad will remain in a lock out status
3. Click on the button to save these changes. If the Lock Out Time is not saved before clicking
any other button or exiting the System Setup window, the data entered is lost and must be re-
entered.
4. You must update the access control network with the new information. Click on the
button on the tool bar (for details on the update process refer to “Update the Network” on
page 35 in section 5).
2.0 Setup Secondary ID Required Time Zones
Once the Dual Verification feature has been enabled, time zones have an additional use. A Secondary
ID Required Timezone must be applied to the Dual Verification reader/keypad defining the hours a
Secondary ID is required to gain access through a door. The process to set up a Secondary ID Required
Timezone is the same as setting up any time zone (see “Setup Time Zones” on page 3 in section 3).
NOTE: A Secondary ID Required Timezone is subject to the Access Timezone applied to the reader/
keypad in Access Groups. If the Secondary ID Required Timezone is set for M-F 8am-8pm, but the
reader/keypad’s access Timezone is set for M-F 8am-6pm, access will be denied from 6pm-8pm.
However, if the Secondary ID Required Timezone is set for M-F 8am-6pm and the reader/keypad’s
access Timezone is set for M-F 8am-8pm, access will be granted with only a Primary ID on M-F
6pm-8pm.