Specifications

Doors
TM
Users Guide Keri Systems, Inc.
12-4 Section 12: Alarm Control 01914-012 Rev. 5.5
Figure 12-3: Alarm Control Option Changed Warning - ON
5. To enable Alarm Control, click on the button. A “Saved Configuration” window
flashes on the screen.
6. Select the type of panel to be used. The default is for Caddx panels. Crow Alarm Panels are
available only in Australia. For all other areas of the world, the selection should be left at the
default of Caddx.
7. To allow access even when the system is armed, click in the “Allow Access When System Armed”
checkbox. The default is for this to not be selected.
8. Now update the access control network with the new information. Click on the button on
the tool bar (for details on the update process refer to “Update the Network” on page 35 in
section 5).
2.0 Configure Reader in Doors
Once the Alarm Control feature has been enabled and the access control network has been updated, two
columns (Alarm Control Reader Type and Allow Access While Alarm System Offline) are added to the
Doors tab in the Setup System window (see Figure 12-4). These columns allow for specific
configuration of the readers associated with the Alarm Control panel.
2.1 Assign Alarm Control Reader Type
1. To assign an Alarm Control Reader Type, click on the Setup System pull-down menu or click
the button on the tool bar. Then click on the Doors tab. The Doors window appears (see
Figure 12-4).
Figure 12-4: Setup System - Doors Tab
2. Scan down the door name and controller/door address columns and locate a door to be assigned an
Alarm Control Reader Type.