Specifications

Keri Systems, Inc. Doors
TM
Users Guide
01914-010 Rev. 5.4 Section 10: EntraGuard 10-31
Figure 10-44: Proximity Card/Key Tag Number
8. Locate the Keri/Wiegand Card Number Range field. Click in the To field. Enter the card number
for the last
card in the range of cards to be enrolled (the highest number).
9. Locate the Facility Code field. Click in the FACILITY CODE field and enter the facility code for
the cards. The default facility code value is 0 (zero).
NOTE: For Keri Proximity cards, facility codes may range from 0 to 31. For 26-bit Wiegand cards,
facility codes may range from 0 to 255. The facility code is programmed into each card. To enroll cards,
you must know the facility code programmed into the card. If you do not know the facility code for the
cards you are enrolling, please contact your card supplier for the facility code number before
continuing the card enrollment process.
NOTE: If you are block enrolling non-Keri Wiegand cards, be sure you know the actual internal card
numbers programmed into the cards and verify the internal numbers are in consecutive order. Using
incorrect numbers and non-consecutive cards invalidate the block enrollment process.
10. The default for User Assigned Card Numbers is to copy the card number from the Keri/Wiegand
Card Number Range field. If there is a need for user assigned card numbers that are different from
the card number printed on the body of the card, locate the User Assigned Card Numbers field.
Click in the Starting field. Enter the user assigned number for the first card in the set. Numbers for
the remaining cards will be assigned in ascending, sequential order from the first number.
11. The resulting window should look similar to Figure 10-45.
Figure 10-45: Enroll Cards Window - Add Cards To Existing EntraGuard IDs
12. Click on the button.