3.1 Field Type and Field Value
The Field Type identifies the type of event data to be retrieved to generate a report. The items in the
Field Type list correspond to information in each event file string. The Field Value is the specific value
of the event data to be retrieved to generate a report.
There are five Field Types; each type having a specific set of Field Values.
• Event sets the search criteria to retrieve events (such as Access Denied, Door Forced, or Request to
Exit). When Event is selected, a pull-down list of all possible events appears for selection in the
Value Field (see “Message Text String Definitions” on page 7 in section 5 for descriptions of all
possible events).
• Time sets the search criteria to retrieve all events that occurred at a specific time. When Time is
selected, the specific time for which to search must be entered in the Value Field.
• Date sets the search criteria to retrieve all events that occurred on a specific date. When Date is
selected, a specific date for which to search must be entered in the Value Field.
• Door sets the search criteria to retrieve all events that occurred at a specific door. When Door is
selected, a pull-down list of all available doors in the access control network appears for selection
in the Value Field.
• Name sets the search criteria to retrieve all events that occurred to a specific user. When Name is
selected, a pull-down list of all available users in the access control network appears for selection in
the Value Field.
• Zone/User/Device (Alarm Control) sets the search criteria to retrieve all events that occurred to a
specific zone, user, or device.
• When Zone is selected, a pull-down list of all available alarm control zones in the access
control network appears for selection in the Value Field.
• When User is selected, a pull-down list of all available users in the access control network
with Alarm Control priveleges appears for selection in the Value Field.
• When Device is selected, a pull-down list of all available alarm control devices in the
access controll network appears for selection in the Value Field.
• Partition Number (Alarm Control) sets the search criteria to retrieve all events that occurred
within a specified partition. When Partition is selected, a pull-down list of all available alarm
control partitions in the access control network appears for selection in the Value Field. If no
partitions have been set up, then the Value Field will remain blank.
• Dept Group sets the search criteria to retrieve all events that occurred to a specific department
group. When a department group is selected, a pull-down list of all available department groups in
the access control network appears for selection in the Value Field. If no department groups have
been entered in the User database, the Value Field will appear blank.