Technical data
34
4.2.3 Standard Supply (concentric horizontal)
Theapplianceissuppliedwithastandardconcentricairandueduct
systemsuitableforuelengthsofupto725mm(28.5in)measuredfrom
the centre of the fan outlet of the boiler to the outside surface of the wall
(or window). The duct assembly is connected to the boiler via a turret
elbow, which can be positioned to exit the boiler in any horizontal direc-
tion (see Fig. 15).
Foruelengthslessthan650mm(25.5in)theoutletterminalductmust
be shortened. Shorten the duct by cutting approximately equal lengths
from both halves as required.
4.2.4 Additional Kits
The following additional concentric kits are available as optional extras
andtheseuekitsmaybeusedwiththestandarduekittogiveanex-
tensiverangeofueoptions.ExamplesareillustratedinFig.14.
a) Extension Duct:
Withtheuseofconcentricueextensionducts(seeFig.14),thetotal
uelengthofthesystemmeasuredfromthecentreofthefanoutletof
the boiler to the outside surface of the wall (or window) can be increased
up to 3000 mm (118 in) (See Fig. 14). Each 1000 mm extension duct
extendstheuelengthby973mm.andeach500mmextensionduct
extendstheuelengthby473mm.
b) 90o Elbow:
Additional90°elbowscanbe addedto theue systemtoallowaddi-
tionalbendsintheuesystemtogivegreaterexibilityinthelocation
of the boiler.
The resistance of the bends must be taken into account when determin-
ing the permissible maximum length of the ue system.A 90o elbow
has an “equivalent length” of 973 mm, one 1000 mm extension duct. No
more than two elbows should be used.
c) Elevation Duct:
Thisistobeusedforelevatedhorizontaluesifrequired.Withstandard
elevation duct, 300 mm elevation is possible from the top of the boiler
before turning to the horizontal direction with elbow.
NOTE: Variations may be used providing that the following rules are
strictly adhered to: