Technical data
32
HARMONY_D USERS INSTALLATION AND SERVICE MANUAL
24
regardless of the wall thickness providing that a suitable wall liner is fitted.
ATTENTION! Flue terminal must be fitted with 3% downward inclination to prevent rain
leaking in to the boiler.
F
G
A
M
A
ME
A
G
F
M
B,C
G
K
F
G
L
K
L
K
B,C
C
F
J
D,N
H,I
G
K
A
Distance to an openable window,air vent or any other ventllation opening from below
B
D
C
E
F
G
H
I
J
K
L
M
N
Distance to roof gutter or drainage and soil pipes from below
Distance to balconies from below
Distance to eaves from below
Horizontal distance to vertical drainage and soil pipes
Distance to inner and outer corners of walls
Distance to adjacent ground or balcony level from above
Distance from a surface facing the terminal
Distance from facing terminals
Horizontal distance to an opening (door/window)under the lean -to roof
Distance to another terminal on the same vertical axis
Distance to an adjacent opening such as a door or window on the same horizontal axis
Distance to lean -to roof from below
Distance to another terminal on the same horizontal axis
300
75
200
200
150
300
300
600
1200
1200
1500
300
600
300
All dimensions are in mm.
O
O
Q
P
R
430 mm
MIN.
O
P
Q
R
From adjacent wall
From adjacent opening window
From another terminal
Minimum height
300
1000
600
300
Figure 13 Flue Terminal Dimensions
See figure 14 to identify the parts of the flue kit. Flue kit item numbers in this figure are used
in the following installation guides.
See figure 14 to identify the parts of the ue kit. Flue kit item numbers in this
figure are used in the following installation guides.