3.5 Turning the boiler OFF
• TurnboththeCHcontrolknobandtheDHWcontrolknobtotheOFF
position.
• TurnthegasandelectricitysuppliestotheboilerOFF.
• IftheboilerisswitchedOFFwhenthereisalikelihoodoffrost;water
in the boiler should be drained off by opening the house central heat-
ing drain tap.
3.6 Central Heating System Discharge
Do the following in case of a discharge of the central heating system
water;
• Turnonthedraintapatthebottomofthecentralheatingsystem.
• Opentheairreleasetapsofradiators.Beginfromtopradiatortobot-
tom one.
• Closetheairreleasetapsafterdrainingthewater.
ATTENTION! It is not recommended to discharge the system except for
the necessary events.
• Whentheboilerisswitchedoffattheswitchonthecontrolpanel,the
word OFF appears on the display. The D.H.W and central heating
frost protection system, nevertheless, remain enabled. If the boiler
was previously on, it is switched off and the post-ventilation, pump
overrun, circulation pump and three-way valve inactivity protection
functions are enabled.
3.7. Topping-up the system with water
The water pressure in the central heating circuit must be checked in
caseofaDHWrequesterrornotication.Thepressuregaugelocated
in front of the pump, should be within the green region and must not be
less than 1 bar.
Ifthereisinsufcientwaterinthe
boiler, the error code F0 (Table 7)
will appear on the display indicat-
ing that there is not enough water
in the system.
Figure 9 Hydraulic Group- Manual filling tab