rotated manually before starting the boiler after a long time of inactivity.
Apply the authorized service to take more information about this pro-
cess.
If you charge the central heating system with hard water, this may cause
blockage of the heat exchanger.
Mains supply water should not exceed 15° French hardness value. To
prevent any corrosion, pH value of the water should be between 8,2
-9,5,conductivityshouldbelessthan30μS/cm,andoxygencontent
should be less than 0,1 gr/m³.
Hot water circuit does not need a pressure relief valve. On the other
hand, pressure should not exceed 6 bars. In case of doubt, a pressure
regulatorshouldbetted.Consultyourinstalleronthisissue.
1.3 Contents of Packaging
The following items below are included in the package. Check if any item
is missing.
• Hangingbracket,connectionscrews(4pcs)andwallplugs(4pcs),
• Installation,operatingandmaintenanceInstructions
• WarrantyDocument,
• StandardFlueSystemissuppliedinaseparatepackage.
1.4 ECONOMY MEASURES
Your boiler is designed and manufactured to minimize the gas consump-
tion.
For further saving below are recommended:
• Yourboilerisadjustedto20.726kcal/hourofoutputcapacity.Down
rating of the heating capacity will save in houses where heating re-
quirement is less. Consult the authorized service for adjustment.
• Use of thermostatic radiator valves or ow balance of radiators
brings additional saving due to homogenous heat distribution over
the house.
• Settingthetemperaturecontrolknobsbetweenthepositions4and
6 reduces fuel consumption. On the other hand, they can be set to