operation manual

EN
Translation of original user instructions EN 2
Improper use
The manometric switch must not be used in
permanent operation. It is not suitable for the
conveying of:
drinking water
salt water
foodstuffs
sewage water
aggressive media, chemicals
corrosive, flammable, explosive or gaseous
liquids
liquids that are warmer than 35 °C
water containing sand and abrasive liquids.
Device description
Manometric switch (Figure A)
1 Connection cable to pump
2 Supply cable with mains plug
3 Manometer
4 Pressure line connection (1" outer thread)
5 "Power" LED
6 “Failure” LED
7 “On” LED
8 "Reset" button
9 Connection to pump (1" outer thread)
Scope of delivery
The manometric switch is delivered complete
with two connection cables.
The installation material for connection to a
pump is not part of the scope of delivery.
Functions of the manometric switch
Automatic operation of the pump
When opening a latch in the pressure line, the
pump is automatically switched on by the mano-
metric switch. If the latch is closed, the mano-
metric switch switches the pump off again, after
achieving the maximum pump pressure.
Protection of the pump from dry running
The manometric switch is equipped with a safety
device, which switches the pump off with insuffi-
cient water.
The switching off takes place after approx. 45 s
and is signalised by illumination of the "Failure"
LED.
Constant flow rate and pressure
The manometric switch ensures a constant flow
rate with constant pressure.
Functional range of the manometric switch
Switch-on pressure approx. 1.8 bar
Switch-off pressure max. 8.0 bar (or maximum
pressure of the pump)
Device setup, start-up
The manometric switch is attached to the pump
output (pressure line connection). The manomet-
ric switch has a 1" outer thread for connection to
the pump.
The manometric switch must only be installed
vertically. If direct attachment to the pump outlet
is not possible for space reasons, a suitable
connector must be used.
The manometric switch can be installed at
any position on the pressure line.
For connecting the pressure line, there is a
connection on the manometric switch with a 1“
outer thread.
Initial start-up
1. Fill pump and suction line up to overflow.
The pump can not be filled over the man-
ometric switch, as a non-return valve is
installed toward the pump.
2. Open a latch available in the pressure line
(valve, spray jet, water tap).
3. Attach the mains plug of the supply cable to
the socket. The pump will begin to operate.
4. Close the latch in the pressure line when
water has flowed out of the line without
trapped air. The manometric switch will au-
tomatically switch the pump off after approx.
15 s. The automatic domestic water system
is ready for operation.