5 Installation
The relay is designed for DIN rail mounting. The operating conditions from the sect. 3.2 must be
taken into account when choosing the installation site. For dimension drawing see Fig. A.1.
Installation:
1. Place the device on a DIN rail as shown in Fig. 5.1.
2. Press the device firmly against the DIN rail in the direction of arrow 2 until the latch locks.
3. Wire the device using the supplied terminal blocks.
Abb. 5.1
Removing:
1. Take off the terminal blocks without disconnecting wires.
2. Insert a screwdriver into the eyelet of the slide interlock.
3. Loosen the slide interlock and then remove the relay from the DIN rail.
5.1 Galvanic isolation
Abb. 5.2 Galvanic isolation
5.2 Wiring
WARNUNG
Electric shock could kill or seriously injure.
All electrical connections must be performed by a fully qualified electrician.
Ensure that the mains voltage matches the voltage marked on the nameplate.
Ensure that the device is provided with its own power supply line and electric fuse.
Do not feed any external devices from the power contacts of the device.
Remove the terminal blocks only after powering off the device and all connected
equipment.