70
Example:
To display the variable VAR1, 4 digits with Auto-precision are reserved. The value
1.546745 will be displayed rounded as 1.547. If the value will be changed to 110.478696,
it will be displayed as 110.5.
6.4.3 I/O box (BOOL)
I/O box (BOOL) is used to display a variable of BOOL type. The value of the variable can
be changed with the device function buttons.
Fig. 6.97
Parameters:
Variable the reference to a variable. Use the icon in the input field to select the vari-
able.
Text TRUE the text displayed if the variable is True
Text FALSE the text displayed if the variable is False
Text before the text to the left of the displayed variable
Text after the text to the right of the displayed variable
Editable if Yes, the displayed value can be changed using the device function buttons
Note: An output variable should be selected. The option has no effect with an in-
put variable.
Length the total number of the reserved characters including the text before and the
text after
Fig. 6.98
6.4.4 Dynamic box
Dynamic box is an output field. It is used to display one of the text rows from a list de-
pending on a row ID. The row ID is saved in a referenced variable of INT type.