Parameters set up:
Location: to select which location the detection device is located,
including Bedroom, Guest room, Hall, Window, Balcony, Kitchen, Study
and Bathroom.
Zone type: to select the type of detection device, including Infrared,
Drmagnet, Smoke, Gas, and Urgency.
Defence delay: it means when users enable the arming mode, there will
be 90 seconds delay time for the alarm mode to be activated.
Alarm delay: it means when the sensor triggered, there will be 90
seconds delay time to announce the notification.
Status: To enable or disable Arming mode on the corresponding Zone.
1.43.4. Configure Alarm Text
After the alarm sensor is set up, you are allowed to customize your alarm text
shown on the screen when an alarm is triggered on web Arming> Zone
Setting > Customized Alarm interface. Enter the alarm text for the alarm at
each location according to your need.