Technical Specifications

Data sheets are subject to change without notice. For the latest version, please check the product page at www.tccmaterials.com
Greater than: > Greater than or equal to: ≥ Less than: < Less than or equal to: ≤
Note: Test results obtained under controlled laboratory conditions at 72°F (22°C)
and 50% relative humidity. Reasonable variations can occur due to atmospheric
and job site conditions.
Applicable Standards:
ASTM C109/C109M Standard Test Method for Compressive
Strength of Hydraulic Cement Mortars (Using 2 in. [50 mm]
Cube Specimens)
ASTM C157-C157M Standard Test Method for Length
Change of Hardened Hydraulic-Cement, Mortar, and
Concrete.
ASTM C191 Standard Test Method for Time of Setting of
Hydraulic Cement by Vicat Needle.
ASTM C882 Standard Test Method for Bond Strength of
Epoxy Resin Systems used with Concrete by Slant Shear.
ASTM C928 Standard Specification for Packaged, Dry, Rapid
-Hardening Cementitious Materials for Concrete Repairs.
Meets or exceeds the compressive strength requirements of
ASTM C387 for high strength mortars.
Available Sizes
10 lb. (4.5 kg) bag (BOM # 102632)
Coverage
10 lb. bag fills a 1 in. wide x ½ in. deep x 30 ft. long crack (2.5
cm x 1.3 cm x 9.4 m), or 10 sq. ft. (0.9 m
3
) at ⅛ in. (0.3 cm)
thickness
10 lb. bag yields approximately 0.09 cu. ft. (.003 m
3
) of
mortar (neat)
5. INSTALLATION
Preparation
Read all directions before starting work. Proper surface
preparation is crucial to achieving a successful application.
1. Remove all loose or unsound materials. Thoroughly clean
surface of dirt, dust, grease, paint, or other contaminants
before patching, topping, or placing overlays.
2. Holes should be chipped out creating a new substrate to
ensure proper bond adhesion.
3. When reinforcing steel is present, it must be free of rust.
Mechanical abrasion or abrasive blasting should be used to
remove rust from reinforcing steel.
4. Large overhead or vertical patches deeper than 2 in. (51 mm)
should contain reinforcing steel. New steel should be inserted
using appropriate techniques of none is present.
5. Just prior to application, pre-dampen surface to be repaired
with clean water to saturated surface dry (SSD) condition with
no standing water remaining.
6. To improve bonding, a slurry coat(a thin soupy mixture of
Instant Patching Cement mixed with water or bonding
additive) can be applied to the pre-dampened surface just
prior to placing the trowelable mixture. Apply with gloved
hand or brush. Allow the slurry coat to become tacky, but not
fully dried. Trowel freshly mixed Instant Patching Cement
over the damp slurry coat and finish as required.
Note: It is the responsibility of the installer/applicator to ensure
the suitability of the product for its intended use.
1. PRODUCT NAME
Akona
®
Instant Patching Cement
2. MANUFACTURER
Akona
Manufacturing, LLC
A TCC Materials Company
2025 Centre Pointe Blvd., Suite 300
Mendota Heights, MN 55120 USA
Phone: 1.651.688.9116
Web: tccmaterials.com
3. PRODUCT DESCRIPTION
Akona Instant Patching Cement is a high-performance cement
used for filling wide cracks and other concrete and masonry
repair needs. It sets rock hard in just 90 minutes. Instant
Patching Cement self-bonds to all properly prepared concrete
surfaces and develops twice the strength of ordinary concrete.
For repairs from in. (3 mm) to 1 in. (25 mm) per application
neat, and can be extended to a maximum of 5 in. (127 mm).
Mix with water or for additional strength and adhesion, mix with
Akona Concrete Bonding Additive (sold separately).
Features and Benefits
Fast, controlled set
High strength
Ideal for deep repairs
Mix with water or bonding additive
When/Where to Use
Interior and exterior concrete repairs
Steps, sidewalks, slabs, patios, and driveways
Walls and floors
4. TECHNICAL DATA
INSTANT PATCHING
CEMENT
High-performance mix for crack filling and repairing cement
Typical Values Akona Instant Patching Cement
Mixed with water
Mixed with Concrete
Bonding Additive
Initial Set Time 10 minutes 30 minutes
Final Set Time 15 minutes 45 minutes
Compressive Strength ASTM C109 (air dry)
3 hours
>1,200 psi
(8.3 MPa)
> 900 psi
(6.2 MPa)
24 hours
> 2,000 psi
(13.8 MPa)
> 1,700 psi
(11.7 MPa)
7 days
> 5,500 psi
(37.9 MPa)
> 3,000 psi
(20.7 MPa)
28 days
> 6,500 psi
(44.8 MPa)
> 6,000 psi
(41.4 MPa)
Slant Shear ASTM C882 modified
24 hours
> 1,000 psi
(6.9 MPa)
> 800 psi
(5.5 MPa)
7 days
> 1 ,500 psi
(10.3 MPa)
>1,500 psi
(10.3 MPa)
28 days
> 2,500 psi
(17.2 MPa)
> 3,500 psi
(24.1 MPa)
Length Change ASTM C157 (typical)
28 days, air < -0.1 < -0.1%
28 days, water < -0.1 < -0.1%

Summary of content (3 pages)