Service manual
Model no.:CT-21CBS5CPH.doc
version 1.0
10
PICTURE TUBE REMOVAL
CAUTION: Do not disturb the deflection yoke or magnet assembly on the picture tube Neck.
Care must be taken to keep these assemblies intact, unless picture tube is being replaced.
Discharge the picture tube to the coating before handing the Tube.
1. Remove chassis, referring to Chassis Removal instructions.
2. Place cabinet front face down on the soft surface.
3. Remove the screw one ach corner of the picture tube and GENTLY lift the picture tube out
of the cabinet.
4. Install a replacement picture tube in reverse order.
5. Properly install the degaussing coil and picture tube grounding lead on the picture tube.
SeeFigure2.
Note: If the Picture Tube is being replaced, mount the Degaussing Coi l on the picture tube. See
following Figure1.Cabinet Back Removal