Use and Care Manual
STEP 5 (Continued)
Gas Conversion 
Changing Burner Nozzles
INSTALLATION TIP: To prevent any omissions, 
remove ALL existing Natural Gas nozzles before 
replacing them with the LP nozzles.
Remove the burner grates, burner caps and burner 
rings. Using a 7mm nut driver, remove ALL the 
existing Natural Gas burner nozzles. Carefully read 
and observe each nozzle label for correct location 
(DO NOT force or over-tighten nozzles as doing so 
Figure 14
WARNING:
Save the natural gas orifices removed from the 
appliance for possible future conversions to natural 
gas. You should use the following process to convert 
to Natural gas. Take extra care when handling steel 
parts.
WARNING:
Care should be taken when removing and replacing 
gas components. Use proper support to prevent 
damage to components.
NG LPG
7 mm
7 mm
Installation
20
7