The resistors 2 x Rv must have a tolerance not exceeding 0.5 % in order
to satisfy the symmetry requirement.
Standardized values for Rv and 2 x Rv:
+ UB Rv 2 x Rv
12 V ± 2 V 680 ohms 330 ohms
24 V ± 4 V 1200 ohms 680 ohms
48 V ± 4 V 3300 ohms 6800 ohms
Phantom powering with unbalanced inputs
If only single ended (grounded) amplifier inputs or no input transformers
are available, either capacitors or optional transformers must be wired
into the audio lines to prevent leakage currents from entering the input
stage.
Specifications:
Transducer Principle: condenser transducer, prepolarized
Polar Pattern: cardioid
Frequency Range: 20 … 20,000 Hz ±3 dB
from published curve
Sensitivity at 1,000 Hz: 7 mV/Pa–0.7 mV/µbar
(–63 dBV, re 1 µbar)
Electrical Impedance: 200 ohms, ±20 % balanced
Recommended Load Impedance:
600 ohms
Hum Sensitivity (at 50 Hz): 4 µV/5 µT
Equivalent Noise Level acc. to
DIN 45412 (A-weighted): 21 dB-A