User's Manual

TRANSMITTER OFF
MAIN CONTACTOR OFF
Depress the STOP button which switches off the transmitter. At the
same time the Main Contactor is deactivated (the Main Contactor of
the traverse cuts out). The operation indicator lamp goes out.
TRANSMITTER LED INDICATIONS
If the transmitter under start up or under drift detect a fault in any
selftests it will indicates with a continuously red light. After what the
transmitter closed down. If it indicates continuously yellow light when
you start up the transmitter it will be something fault with some of the
manipulators.
INDICATIONS EXPLANATIONS
Green flashing Drift
Yellow flashing Accumulatorvoltage low < 6,9 V
Yellow continuously Discharge accumulator voltage < 6.1 V
Red continuously Fault, see the productdescription
MANUAL MC8318 No. 923477-000 USA
Version: A0 Approved by: HH
Page. 7 (12)
RUN DOWN ACCUMULATOR
The transmitter is equipped with an indicator lamp (green and yellow)
for accumulator status. The lamp blinks green when the accumulator
voltage is normal(?7,2V), but starts to blink yellow when it falls
(<6,9V). When the indicator lamp has started blinking yellow the
transmitter can be operated approx. 10 min., before the voltage is so
low (<6,1V) that the transmitter switches off automatically. This is
indicated by the indicator lamp showing fixed yellow light.
The two last-mentioned statuses are also present at outlets in the
receiver.
MANUAL MC8318 No. 923477-000 USA
Version: A0 Approved by: HH
Page. 8 (12)