Instruction Manual

This varies the amount of control voltage passed from the Emp. CV Input (14) to the lter
core and it’s range is 0% to 100%. The manual Emphasis Level control (13) is still active
when using external CV control of Emphasis and acts as an oset control.
This is the audio output for the signal after passing through the lter core and would
typically be connected to the Audio Input of a VCA. The output level is dependent upon
the input level, with a single input of +/- 5V to (for example) Audio Input 1 and Audio 2
Level at 100% the gain would be unity, i.e. output would also be +/- 5V.
Power Cable
Copyright © AJHSynth 2014
A Scale Adjust :
Sets the 1V/Oct voltage scaling. To adjust, rst remove all inputs, then turn Emphasis
Level (13) to 10 (full on) and adjust Frequency Control (7) for 440hz output. Now apply
EXACTLY 2V to the 1 V/Oct input and adjust for 1760Hz output (precisely 2 octaves
higher).
B Regen Adjust :
With no inputs, set Emphasis Level (13) to 10 (full on) and adjust Frequency Control (7) for
440Hz. Now turn Empahsis Level to 8 and turn Scale Adjust Trimmer until the lter just
starts to selfsoscillate.
C Oset Adjust :
Adjusts the vactrol circuit oset. FOR MANUFACTURER ADJUSTMENT ONLY, specialist
test equipment is needed to calibrate this trimmer correctly.
D Range Adjust :
Sets the frequency range. To adjust remove all Inputs, set Emphasis Level (13) to 10 (full
on) and set Cuto Frequency (7) to -1 position. Adjust trimmer for 440Hz output.
E Gain Jumper :
See previous page.
Note:
This information is given for completeness, the MiniMod VCF is calibrated after manufacture
and under normal circumstances should not require any user adjustment.
Adjustment and Calibration
A Scale Adjust
Red Stripe aligns with -12V as shown
B Regen Adjust
C Oset Adjust
D Range Adjust
E Gain Jumper
If you need any help using this module or have any technical questions please feel free to
contact us at support@ajhsynth.com