Manual (englisch)
This varies the amount of control voltage passed from the Emp. CV Input (14) to the lter 
core and it’s range is 0% to 100%. The manual Emphasis Level control (13) is still active 
when using external CV control of Emphasis and acts as an oset control. 
This is the audio output for the signal after passing through the lter core and would 
typically be connected to the Audio Input of a VCA. The output level is dependent upon 
the input level, with a single input of +/- 5V to (for example) Audio Input 1 and Audio 2 
Level at 100% the gain would be unity, i.e. output would also be +/- 5V. 
Power Cable
Copyright © AJHSynth 2014
A Scale Adjust : 
Sets the 1V/Oct voltage scaling. To adjust, rst remove all inputs, then turn Emphasis 
Level (13) to 10 (full on) and adjust Frequency Control (7) for 440hz output. Now apply 
EXACTLY 2V to the 1 V/Oct input and adjust for 1760Hz output (precisely 2 octaves 
higher). 
B Regen Adjust : 
With no inputs, set Emphasis Level (13) to 10 (full on) and adjust Frequency Control (7) for 
440Hz. Now turn Empahsis Level to 8 and turn Scale Adjust Trimmer until the lter just 
starts to selfsoscillate. 
C Oset Adjust : 
Adjusts the vactrol circuit oset. FOR MANUFACTURER ADJUSTMENT ONLY, specialist 
test equipment is needed to calibrate this trimmer correctly.
D Range Adjust : 
Sets the frequency range. To adjust remove all Inputs, set Emphasis Level (13) to 10 (full 
on) and set Cuto Frequency (7) to -1 position. Adjust trimmer for 440Hz output.
E Gain Jumper : 
See previous page.
Note: 
This information is given for completeness, the MiniMod VCF is calibrated after manufacture 
and under normal circumstances should not require any user adjustment. 
Adjustment and Calibration
A Scale Adjust
Red Stripe aligns with -12V as shown
B Regen Adjust
C Oset Adjust
D Range Adjust
E Gain Jumper
If you need any help using this module or have any technical questions please feel free to 
contact us at support@ajhsynth.com