User Manual

Relay Mode
Settings are available with rmware version
5.54.1.0 and higher
Contact status
Normal contact state
Pulse duration
Selecting the pulse duration in the pulse mode:
From 0.5 to 255 seconds
Current protection
If active, power supply will be switched off if
current exceeds 13 A, in the inactive state the
threshold is 19,8 A (or 16 A, if continues for 5
seconds)
Voltage protection
If active, power supply will be switched off in case
of a voltage surge beyond the range of 184 – 253
V, in the inactive state — 0 – 500 V
Scenarios
Opens the menu for creating and conguring
scenarios
Jeweller Signal Strength Test
Switches the device to the Jeweller signal
strength test mode
User Manual Opens the WallSwitch User Manual
Allows the user to deactivate the device without
removing it from the system. The device will not
execute system commands and participate in
automation scenarios. All notications and
Bistable — WallSwitch, when activated,
changes the state of contacts to the opposite
Normally closed
Normally open
Learn more