Actuating element Electromagnetic relay
The service life of the relay 200,000 switching-ons
Supply voltage 110 – 230 V AC ± 10% 50/60 Hz
Voltage protection
For 230 V mains: max — 253 V, min — 184 V
For 110 V mains: max — 126 V, min — 77 V
Maximum load current 13 А
Maximum current protection Yes, 13 A
Power output (resistance load 230 V) Up to 3 kW
Operating modes
Pulse and bistable (rmware version is 5.54.1.0
or higher. Manufacture date from March 5, 2020)
Only bistable (rmware version under 5.54.1.0)
Pulse duration
0.5 to 255 seconds (rmware version is 5.54.1.0
or higher)
Electricity meter function Yes
Power consumption
parameters control
Yes: current, voltage,
consumed power
The power consumption of the device in the
standby mode
Less than 1 W