WallSwitch User manual Updated December 7, 2021 WallSwitch is a wireless indoor power relay featuring a power consumption meter. The miniature body of the device is adapted for installation in a European-type socket. Regardless of the type of electrical circuit, only a quali�ed electrician should install WallSwitch! WallSwitch operates only within the Ajax security system (integration into thirdparty security systems is not provided), communicating with a hub via the protected Jeweller protocol.
How to create and con�gure a scenario in the Ajax security system The Ajax security system can be connected to the central monitoring station of a security company. Buy power relay WallSwitch Functional Elements 1. Antenna 2. Terminal blocks 3. Functional button 4.
IN terminals: • L terminal — power supply phase terminal. • N terminal — power supply neutral terminal. OUT terminals: • N terminal — connected device neutral output contact terminal. • L terminal — connected device phase output contact terminal. Operating Principle WallSwitch input terminals are connected to the grid, and the output terminals are connected to the socket or electrical appliance/system.
• Normally open (NO) — the contacts close when the relay is activated and open when the relay is inactive. WallSwitch, with �rmware version below 5.54.1.0, only works in bistable mode with a normally open contact. How to �nd out the �rmware version of the device? At low loads (up to 25 W), current and power consumption indications may be displayed incorrectly due to hardware limitations. Connecting to the hub Before connecting the device: 1.
3. Click Add — the countdown will begin. 4. Press the functional button. If you can’t do this (the device is mounted in the wall), give WallSwitch at least 20 W load for �ve seconds (by connecting and disconnecting a working kettle or lamp). For detection and pairing to occur, the device should be located in the coverage area of the hub’s wireless network (at the same object). The connection request is transmitted only at the moment of switching on the device.
Parameter Value Jeweller Signal Strength Signal strength between hub and device Connection Connection status between hub and device Displays the status of using a radio Routed Through ReX signal range extender Active State of the relay (switched on/off) Voltage The input voltage of WallSwitch Current The input current of WallSwitch Power Current consumption in W Electric energy consumed The electric power consumed by the device connected to the relay.
Relay Mode • Bistable — WallSwitch, when activated, changes the state of contacts to the opposite Settings are available with �rmware version 5.54.1.0 and higher Normal contact state Contact status • Normally closed • Normally open Selecting the pulse duration in the pulse mode: Pulse duration From 0.
Indication The WallSwitch light indicator can light green depending on the device status. When not paired with the hub, the light indicator blinks periodically. When the functional button is pressed, the light indicator lights up. Functionality testing The Ajax security system allows conducting tests for checking the functionality of connected devices. The tests do not start immediately but within a period of 36 seconds when using default settings.
Installation process: 1. De-energize the cable to which WallSwitch will be connected. 2. Connect the grid wire to the WallSwitch terminals according to the following scheme: 3. Connect a socket using bundled connecting wires or an electrical appliance using a wire with the su�cient cross-section to WallSwitch. It’s recommended to use wires with a cross-section of 1.5 – 2 mm². Do not connect more than 3 kW load to WallSwitch.
1 — recommended antenna location Do not shorten the antenna! Its length is optimal for operation within the used radio frequency range! During the installation and operation of WallSwitch, follow the general electrical safety rules and the requirements of electrical safety regulatory acts. It is strictly forbidden to disassemble the device. Do not use the device with damaged power cables. Do not install the WallSwitch: 1. Outdoors. 2. In metal wiring boxes and electrical panels. 3.
Actuating element Electromagnetic relay The service life of the relay 200,000 switching-ons Supply voltage 110 – 230 V AC ± 10% 50/60 Hz Voltage protection For 230 V mains: max — 253 V, min — 184 V For 110 V mains: max — 126 V, min — 77 V Maximum load current 13 А Maximum current protection Yes, 13 A Power output (resistance load 230 V) Up to 3 kW Pulse and bistable (�rmware version is 5.54.1.0 or higher. Manufacture date from March 5, 2020) Only bistable (�rmware version under 5.54.1.
Modulation GFSK Up to 1,000 m (any obstacles absent) Radio signal range Learn more Shell protection rating IP20 Operating temperature range From 0°С to +64°С Maximum temperature protection Yes, 65°C Operating humidity Up to 75% Overall dimensions 39 × 33 × 18 mm Weight 30 g Service life 10 years Compliance with standards Complete Set 1. WallSwitch 2. Connecting wires — 2 pcs 3.
Technical support: support@ajax.