Specifications

OM-229 158 Page 33
VLnA-B This is the approximate phase to phase line voltage between phases A and B.
VLnB-C This is the approximate phase to phase line voltage between phases B and C.
VLnC-A This is the approximate phase to phase line voltage between phases C and A.
VBus This is the DC bus voltage.
Therm1 This is the temperature of the current source primary heatsink.
Therm2 This is the temperature of the bridge heatsink.
Therm3 This the the temperature of the current source secondary heatsink.
Therm4 Open (not used).
Therm5 Open (not used).
ExtInt This is the status of the relay contacts for a remote protection device..
OFF
ON
The third diagnostic screen is available by again pressing and holding the Run Status button and pressing the Parameters
Hz
V
A
kW
button.
This screen displays the values of cycles and running time. Cycle Counts and RunTime can be reset to zero (0). Lifetime Cycles and Lifetime Run
Time values cannot be reset.
Cycle Counts.....: 0 CYCLES
Lifetime Cycles..: 0
RunTime.........: 0d 0h 0m 0.0s
Lifetime RunTime: 0d 0h 0m 0.0s
Press the Increase or Decrease button simultaneously to reset Cycle Counts and RunTime.
Press Program
to reset cycle counts
Press the Program button and the cycle counts and run time will be reset to zero (o).