Specifications

OM-229 158 Page 21
SECTION 6 SETUP AND OPERATION
6-1. Safety Equipment
Wear the following during
operation:
1. Dry, Insulating Gloves
2. Safety Glasses With Side
Shields
DO NOT wear rings, watches, or
other metallic items during opera-
tion. sb3.1* 1/94
12
6-2. System Description
The Toccotron AC is intelligent to the point that it will automatically adjust output power levels if internal system operating parameters or internal temper-
atures reach or exceed specific set limits (see Section 9).
6-3. Power Source/System Setup
To view the System Setup screen, simultaneously press the Parameters
Hz
V
A
kW
and Program buttons and the following screen appears on
the display:
Time Resolution: Seconds SETUP1
KW Second Alarm: No Min: 0 Max: 9999
KW Second Scale: x1 ExtInterrupt: YES
Remote Enable..: No
System Lock.: No SETUP2
Control Mode: Timed Command: Power
Max KW......: 35 Degree Units: F
Backlight...: Yes Isolation Detect: Yes
To change a setting:
Press the Cursor button to move the cursor to the parameter to be changed
Press Increase or Decrease button to select desired setup feature.
Possible selections Setup 1:
Time Resolution in seconds 0.1 second increments
KW Second Alarm Yes/No Minimum: 09999, Maximum: 09999
KW Second Scale x1, x10, x100 External Interrupt Yes/No
Remote Enable Yes/No