4-13. Secondary Insulation Protection
! Connect ground lead(s)
between the workpiece and
power source to provide
proper secondary insulation
protection from a short in the
output circuit.
Secondary insulation protection
circuitry automatically shuts down
the power source output if a
potentially hazardous condition
exists at the heating device
connected to the power source (e.g.
insulation has broken down on a
heating coil causing the conductor to
come into contact with the workpiece
or a heating coil touches the
workpiece causing a short in the
output circuit).
This circuitry must be enabled before
this feature is available. See Section
6-3.
1. Receptacles
2. Plug
To connect plug, align key with key-
way, insert end into receptacle, and
rotate plug until tight.
3. CustomerSupplied Handle
4. CustomerSupplied Magnet
The secondary isolation magnet
must be in contact with bare
metal (free from rust, paint,
grease, etc.).
5. Workpiece
Use handle to place magnet on the
workpiece.
3
4
5
1
2