www.aja.com R10CE Universal Monitoring D/A Converter R-series Card Module Published: 6/30/10 Installation and Operation Guide B e c a u s e i t m a t t e r s .
Trademarks AJA®, KONA®, Ki Pro®, and XENA® are registered trademarks of AJA Video, Inc. FiDO™, Io HD™ and Io™ are trademarks of AJA Video, Inc. HDMI, the HDMI logo and High-Definition Multimedia Interface are trademarks or registered trademarks of HDMI Licensing LLC. DVI is a registered trademark of DDWG. All other trademarks are the property of their respective holders. Notice Copyright © 2010 AJA Video, Inc. All rights reserved. All information in this manual is subject to change without notice.
AJA Universal Monitoring D/A Converter User Manual Introduction The R10CE SDI monitoring distribution amplifier provides four equalized, reclocked and separately buffered serial digital outputs, plus four analog monitoring outputs. One analog output is NTSC/PAL. The other three analog outputs are configurable to a wide variety of formats, including composite, composite and Y/C (S Video), or component—including SMPTE/N10 (YUV), RGB, and true Betacam levels.
Block Diagram Set by Switches Composite Cable EQ ReClock PLL Jitter Filter D/A Conversion Deserializer SD Input Y G - Composite Pb B Y Composite Pr R C Composite Comp Out Comp/-/G/Y Out Analog (Component or Composite) Comp/Y/B/B-Y Out Comp/C/R/R-Y Out Serial Out 1 Serial Out 2 Serial Out 3 Serial Out 4 Cable Drivers R10CE Monitoring Digital DA, Simplified Block Diagram I/O Connections Comp/ -/G/Y Out Comp/ C/R/Pr Out SDI Out 1 SDI Out 3 SDI In J1 SDI Out 1 J2 SDI Out 2 J3
AJA Universal Monitoring D/A Converter User Manual User Controls The user interface for configuring the R10CE and selecting output formats is a 6-position DIP switch at the front of the card. Two LEDs at the front of the card additionally show the type of input present (525 or 625), which happens automatically. DIP Switch The four outputs labeled Serial Out 1-4 are always serial digital. They are cable-equalized, and reclocked. The “Comp” outputs are format configurable via the S1 and S2 DIP switches.
Output Selection Matrix For Output 3 BNCs Switch Number Description Details S6 — TEST Enable or disable test pattern output OFF (UP) = Disables internal test signal ON (DOWN) = Selects internal 75% colors bars test signal The following table shows the combinations of DIP switch settings required to choose output formats for the three configurable output BNCs.
AJA Universal Monitoring D/A Converter User Manual Specifications Item Specification Input: SDI (SMPTE 259M), BNC Outputs: SDI (SMPTE 259M), 4 x BNC NTSC/PAL Analog, 1 x BNC YPbPr - SMPTE, EBU-N10, Betacam RGB, or 3 x NTSC/PAL, or 1 NTSC/PAL and Y/C (S Video) 3 x BNC All outputs are separately buffered Serial Output: Equalized, Re-clocked Jitter Filtering: Up to 2.5 Hz Frequency Response: +/-.25db to 5Mhz frequency response (Y) 2T K factor: <1% (Y) Diff. Gain: <1.5% Diff. Phase: <1.
Appendix A: Safety & Compliance Federal Communications Commission (FCC) Compliance Notices Class A Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15, Subpart B of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation.
AJA Universal Monitoring D/A Converter User Manual European Union and European Free Trade Association (EFTA) Regulatory Compliance This equipment may be operated in the countries that comprise the member countries of the European Union and the European Free Trade Association.
Korea KCC Compliance Statement Taiwan Compliance Statement This is a Class A product based on the standard of the Bureau of Standards, Metrology and Inspection (BSMI) CNS 13438, Class A. Japanese Compliance Statement 1. Class A ITE この装置は、 クラスA 情報技術装置です。 この装置を家庭環境で使用すると電波妨害 を引き起こすことがあります。 この場合には使用者が適切な対策を講ずるよう要求され ることがあります。VCCI−A This is a Class A product based on the standard of the VCCI Council (VCCI V-3/2008.04).
AJA Universal Monitoring D/A Converter User Manual Before operating your unit, please read the instructions in this document Warning! Read and follow all warning notices and instructions marked on the product or included in the documentation. Avertissement ! Lisez et conformez-vous à tous les avis et instructions d'avertissement indiqués sur le produit ou dans la documentation.
¡Advertencia! No instale cerca de fuentes de calor tales como radiadores, registros de calor, estufas u otros aparatos (incluidos amplificadores) que generan calor. Aviso! Não instale perto de nenhuma fonte de calor tal como radiadores, saídas de calor, fogões ou outros aparelhos (incluindo amplificadores) que produzam calor. Avviso! Non installare vicino a fonti di calore come termosifoni, diffusori di aria calda, stufe o altri apparecchi (amplificatori compresi) che emettono calore.
AJA Universal Monitoring D/A Converter User Manual Attenzione! Questo dispositivo è un prodotto di Classe A. Il funzionamento di questo apparecchio in aree residenziali potrebbe causare interferenze dannose, nel cui caso agli utenti verrà richiesto di adottare tutte le misure necessarie per porre rimedio alle interferenze a proprie spese. Warning! Disconnect the external AC power supply line cord(s) from the mains power before moving the unit.
Warnung! Hinweis zum FR2 mit doppeltem Netzkabel – bitte beachten. Um das Risiko eines Elektroschocks zu verringern, sind beide Netzkabel vor der Wartung des Geräts abzutrennen. ¡Advertencia! Aviso: Cable eléctrico FR2 dual — Por favor leer. Para reducir el riesgo de electrocución, desconecte ambos cables eléctricos antes de reparar el equipo. Advertência! Aviso do cabo duplo de alimentação FR2 — leia isto.