Specifications
14
Using Dipswitches to Control the Hi5-3D
In addition to the Mini-Config application discussed earlier, you can
also control the unit via an 8-switch DIP, accessible through a cut-out in
the bottom of the unit.
The exact function of each DIP switch and what it controls is described
on the following pages.
Switch 1 (CONTROL)—This switch determines whether
the Hi5-3D is configured via dipswitch or Mini-Config
software
:
Switch 2 (H FLIP LT)—Controls Horizontal Flip of Left Eye Input
:
Switch 3 (V FLIP LT)—Controls Vertical Flip of Left Eye Input
:
Switch 4 (H FLIP RT)—Controls Horizontal Flip of Right Eye Input
:
Switch 5 (V FLIP RT)—Controls Vertical Flip of Right Eye Input
:
LOCAL (LEFT) REMOTE (RIGHT)
When in “Local” mode, the
remaining dipswitches will
support a subset of the
user controls
When in the “Remote” mode, the
normal Mini-Config non-volatile
registers (as last set), control the
unit
OFF (LEFT) ON (RIGHT)
The left eye input is not flipped
horizontally
The left eye input is flipped
horizontally
OFF (LEFT) ON (RIGHT)
The left eye input is not flipped
vertically
The left eye input is flipped vertically
OFF (LEFT) ON (RIGHT)
The right eye input is not flipped
horizontally
The right eye input is flipped
horizontally
OFF (LEFT) ON (RIGHT)
The right eye input is not flipped
vertically
The right eye input is flipped
vertically
1 2 3 4 5 6 7 8
DIP Switch Setting
LEFT RIGHT