Service manual
– 6 –
When repairing the Flat TV, never switch ON the main POWER with the degauss coil removed.
If the degauss coil must inevitably removed due to some reason, connect a dummy using either Method 1 or
Method 2 as described below.
Method 1: Prepare a replacement degauss coil and connect it during repair.
Method 2: Prepare a resistor of 2.8 ohm, 20 W. Manufacture a repair jig by connecting it to the degauss side
connector. Connect the jig during repair.
Waning
If the main POWER is switched ON without connecting degauss coil or dummy resistor, the cement resistor
R801 that is connected in parallel with the degauss coil burns to open.