Technical information

Chapter 1 27
Regulatory Requirements Safety Requirements:
1.The subject product rated 100-120V 60Hz must be listed under UL 1950
and certified with SCA Standard C22.2 No.950.
2.The subject product rated 200-240V 50Hz must comply with low voltage
directive 73/23EEC.
EMI Requirements:
1.The subject product rated 100-120V 60Hz must meet the EMI
requirements of FCC part 15, Subpart B for Class B Digital Device and get
FCC Certification before marketing into USA and Canada.
2.The subject product rated 200-240V 50Hz must meet the EMC Directive
89/336/EEC.
3.The subject product rated 100-120V must meet the VCCI-2 EMI
requirements.
Power Management
Power Saving Mode Phenomenon
Standby Mode
Waiting time specified by the System
Standby value or the operating system
elapses without any system activity.
Or
When the computer is about to enter
Hibernation mode (e.g., during a battery-low
condition), but the Hibernation file is invalid
or not present.
T The Sleep indicator lights up
Hibernation Mode
When customized functions for power
management are set to
Hibernation
and the
corresponding action is taken.
T All power shuts off
Display Standby Mode
Keyboard, built-in touchpad, and an external
USB pointing device are idle for a specified
period.
T The display shuts off
Environmental Requirements
Item Specification
Temperature
Operating
+5~+35
°
C
Non-operating
-10~+60
°
C
Non-operating
-30~+60
°
C (storage package)
Humidity
Operating 20% to 80% RH, non-condensing
Non-operating 20% to 80% RH, non-condensing (unpacked)
Non-operating 20% to 90% RH, non-condensing (storage package)
Vibration
Operating (unpacked) 2~200Hz: 0.40Grms
Non-operating (unpacked) 2~200Hz: 0.80Grms
Non-operating (packed) 2~200Hz: 1.00Grms
Shock
AC Adapter