Installation Instructions

10
Gertraudenstraße 10-12, 10178 Berlin
Email: info@aisight.de
Phone: +49 (0) 30 40363399 V1.0
10
3.2. Powering
Two options to power up the sensor can be used depending on how the customer prefers
and how the contract between the two parts was agreed. The first option is to use the custom
AC power supply compatible with the product, the TRE25R240 with 3m long cable and
female M8 4 pin connector, as shown in Figure 4.3.
Figure 4.3 - AiSight custom power supply with M8 connector
In cases where AC connection is not possible close to the machine (either by physical or
safety constraints) the customer can also use a 2-wire or 4-wire cable with M8 4-pin female
connector to directly connect the sensor node from existing machine panels or switchboards
that has DC connection from 8 to 48V (24V recommended). A cable with an overmolded
connector can be used or a cable with a field installable connector, as shown in Figure 4.4.
For either case, the cable must be designed for industrial use, have internal and external
insulation jackets and have the UL94-V0 or higher.
The sensor node consumes a maximum of 3W and supports a power supply voltage from 8
to 48Vdc, with a preferred supply of 24Vdc.
Figure 4.4 - Example of a cable with M8 female plug connector