6.5. Software Installation
6.5.1 Calibration of the Touch Screen
6.5.1.1 Calibrating of the Touch Screen
Calibration serves two purposes:
o Sets the active area of the touch screen.
o Aligns the active area of the touch screen to the screen’s image.
Before you calibrate the touch screen, let the system warm up for 30 minutes.
Calibration aligns the active touch-sensitive area of the touch screen with the image on the display. Calibration also
determines the edges of the screen’s image and locates the center of the touch screen. If the touch screen is not
calibrated properly, the active area of the touch screen may not be aligned with the screen’s image or may be
unnecessarily small in size.
6.5.1.2 Calibrate the Touch Screen
The touch screen of in the Operator Interface Computer 10"/15"/17” NEMA4 system, IP10IA99 / IP15IA99 /
IP17IA99, is calibrated at the factory. The Touch Screen Utility” has been installed in the Operator Interface