Technical data

   Page 42
in the housing for the AC/DC adapter)
3
Threaded h
oles for securing the housing
with AC/DC adapter to the wall mount plate
7
4
x mounting holes for the DIN Rails clip that
allow the clip mounting
4
Latch with captive screws, slotted flat
head
for securing the
housing
with AC/DC adapter
to the wall mount plate
8
DIN Rail clip
In order to attach the AC/DC adapter (Fig.5-27) onto the wall mount plate, follow these steps (Fig.6-11):
1. Insert the AC/DC adapter (Fig.5-27) into the cavity of the AC/DC adapter enclosure (Fig.6-12).
2. Position the enclosure (with inserted AC/DC adapter) against the wall mount plate and slide the enclosure carefully
downwards in order to hook the anchor latches of the enclosure (#6, Fig.6-12) into the anchor slots (#2, Fig.6-11).
3. The enclosure will be shifted downwards until the latch with captive screws of the enclosure (#4, Fig.6-12) and the
threaded holes (#3, Fig.6-11) of the wall-mount plate are aligned.
4. Tighten on the captive screws. The captive screws must be firmly tightened.
6.3 Getting started
The Operator Interface Computer 10"/15"/17” NEMA4 system, IP10IA99 / IP15IA99 / IP17IA99, is designed to be
powered from a DC power source via the included DC power cable. In order to use an AC power source as main
power source, an AC/DC adapter (not included) can be ordered.
- Before using your system, you should first become familiar with the system components and check that
everything is connected properly. Following a proper cabling procedure will prevent a false power-on
condition, which could result in unit operational failure.
- Also, it is recommended that the last cable attached to the system should be the power cable.
6.3.1 Connecting to DC Power Source
The Operator Interface Computer 10"/15"/17” NEMA4 system, IP10IA99 / IP15IA99 / IP17IA99, will be connected
to DC power source using the supplied DC power cable (refer to Fig.5-26)
Fig.6-15 Connecting to DC power source with open lead cable