Technical data

   Page 27
Electrical Specifications for the AC/DC Adapter
AC Input
DC Output
100-240V
1.2A
50-60Hz
24V DC
3.125A
For connecting to the system and power refer to “Connecting to Power”.
Electrical Specifications for the Panel System
System Type
Product
Input
Operator Interface Computer
10"/15"/17” NEMA4 system
IP10IA99 24V DC 1.49A max.
12V DC 2.93A max.
IP15IA99 24V DC 1.73A max.
12V DC 3.46A max.
IP17IA99 24V DC 2.18A max.
12V DC 4.16A max.
5.8. Accessing Internal Components
This section contains important information that you must read before accessing the internal components. You
must follow these procedures properly when handling any board components of the system.
Before removing the cover of the Operator Interface Computer 10"/15"/17NEMA4 system, IP10IA99 /
IP15IA99 / IP17IA99, in order to gain access to the internal components, the system must be powered-down
and the power cord has to be disconnected from the power source.
The system may only be opened in accordance with the description in this user’s manual for:
Configuration of the RS422 / RS485 interface. (Refer to COM port mode by BIOS setting)
These procedures have to be carried-out only by qualified specialist personnel.
It is not allowed to operate the system without installed cover.
Please observe the safety instruction for handling assemblies with static sensitive device. Failure to take heed
of this warning instruction can result in damage to the device.
6. System Installation
The Operator Interface Computer 10"/15"/17NEMA4 system, IP10IA99 / IP15IA99 / IP17IA99, is delivered
with pre-installed operating system. According to the ordered system configuration all drivers are installed. The
system is fully operational at the first start-up.
6.1 H/W Installation
6.1.1 Jumping Setting
You may configure the Operator Interface Computer 10"/15"/17” NEMA4 system, IP10IA99 / IP15IA99 / IP17IA99,
to match the needs of your application by setting Jumpers on Main board. To select any option, cover the jumper cap
over (SHORT) or remove (NC) it from the jumper pins according to the following instructions. Here NC stands for “Not
Connect”.